simple site creator

PC3414 Controller for Rail Vehicles

EN 50155 Compliant Programmable Controller for Rail Applications on Rail Vehicles.

• Passenger Vehicle Condition Based Monitoring.
• Heating Ventilation Air Conditioning (HVAC) Control Systems.
• Onboard controls for fire protection, power packs and doors.
• Locomotive Performance and Condition Monitoring.
• Trackside Monitoring and SCADA.
• Industrial Control Systems.

• 10/100 Mbps Wired Ethernet in accordance with IEEE 802.3 via M12 D-Code connector.
• One RS232 serial communications port.
• One isolated RS485 serial communications port.
• 24 Digital Inputs 1mA @ 110VDC.
• 24 Digital Outputs 1A @ 110VDC.
• 6 Analogue Inputs. Configured as: NTC Thermistor (Ch1... Ch3); 0-20mA (Ch4... Ch6).
• 2 Analogue Outputs. Configured as: 0-12V (Ch1... Ch2). 
• Suitable for nominal battery voltages of  110VDC in accordance with EN 50155. 
• Operating temperature range: -40°C to +70°C (+85°C for 10 minutes). 
• Connections for RS232 and RS485 via DB9 female connectors. 
• Connections via cage clamp plug socket connectors.
• Conformal Coating. 
• EN 50155 Compliant.

Environmental:

• Operating Temperature Range: -40°C to +70°C (EN50155 Class OT4).
• Switch-on Extended Operating Temperature Range: To +85°C for 10 minutes (EN50155 Class ST1).
• Storage Temperature Range: -40°C to +85°C.
• Relative Humidity: 5% to 95% non-condensing.
• Shock and Vibration: EN 61373:2010 Category 1 – Class B.

Power Supply:

• Nominal Input Voltage: 110 VDC.
• Minimum Input Voltage: 66 VDC (EN50155 Class C1).
• Maximum Input Voltage: 154 VDC.
• Nominal Input Current: 13 mA. 

Processor Features:

• Processor: Freescale Vybrid VF50N, CPU clock: 400MHz, DMIPS: 628.
• NAND Flash: 128 MB.
• DDR3 RAM: 128 MB.
• Non-volatile SRAM: 128 kB.
• Non-volatile Real Time Clock with Supercap.

Communications Ports:

• Ethernet: 10/100 Mbps IEEE 802.3.
• Non-isolated RS232 (TIA-232F): Five-wire with RxD, TxD, RTS and CTS signals.
• Isolated RS485 (TIA-485): Three-wire: A, B and SG. Isolated to 500 VAC.

Digital Inputs:

• Twenty-four (24) digital inputs 1mA @ 110VDC. Current sinking (high-side switching).

Digital Outputs:

• Twenty-four (24) digital outputs 1A Current sourcing (high-side switching). Short circuit protection with automatic reset.

Analogue Inputs:

• Six (6) channels 12-bit resolution. Configured as: NTC Thermistor (Ch1... Ch3); 0-20mA (Ch4... Ch6).

Analogue Outputs:

• Two (2) channels 10-bit resolution. Configured as: 0-12V (Ch1... Ch2).

Mechanical:

• Enclosure Material: Extruded Aluminium with Anodised Screen Printed Lid.
• Product dimensions: 223mm x 341mm x 63mm (with plug connectors installed).
• Weight: 1.7 kg (without plug connectors).

Ingress Protection (IP) Rating:

• IP20 (in accordance with EN 60529).

Reliability:

• MTBF: 236,574 hrs @ 40°C Standard: Telcordia SR-332 Issue 2 – Parts Count Method.

Terminations:

• Plug/socket cage clamp connections (2.5 mm² max.) on a 5.08mm pitch.
• Ethernet: M12 D-Coded Female. 
• RS-232 and RS-485: DB9 Female. 

Standards:

• EN 50155:2017 Railway Applications – Electronic Equipment used on Rolling Stock. 
• EN 50121-3-2:2016 Railway Applications – Electromagnetic Compatibility Part 3-2: Rolling Stock – Apparatus.
• EN 61373:2010 Railway Applications Rolling Stock Equipment Shock and Vibration Tests.
• EN 45545-2:2013+A1:2015 Railway Applications – Fire Protection for Railway Vehicles. Part 2: Requirements for Fire Behaviour of Materials and Components.

Materials Compliance:

• REACH, ROHS, WEEE, EN45545-2.

Programming:

• Linux “C” API’s. 
• iecTeso (ISaGRAF) IEC61131-3 Programmable.

Mobirise

Talk to our technical sales staff about your product vision.

MORE INFORMATION

Address

Unit 13, 82 Reserve Rd.
Artarmon, NSW 2064
Australia

Contacts

Email: sales-aus@duagon.com
Phone: +61 2 9966 9424
Fax: +61 2 9966 9429

Links

News 
Events 
Contact